Dev notes
Before an endovascular aneurysm repair, someone sits with the CT and measures: how wide the aorta is just below the renal arteries, how long that healthy neck runs before the aneurysm starts, how big the sac gets, how wide each common iliac is. Those numbers decide whether a stent graft fits and which one. It's a skill you get better at by doing it and being told how far off you were, and the second half is the part that's hard to come by. So I built EVAR Sizing: scroll the axial slices, put calipers down, record five measurements, and get each one checked against an exact answer. It lives at medical.paulsumido.com now, in a project of its own.
The obvious version uses deidentified patient CTA. There are openly licensed aortic datasets with segmentations, and that is still where I want this to go. What stopped me for the first cut wasn't licensing or file size, though both matter. It was the answer key. A segmentation tells you which voxels are aorta. It doesn't tell you where the neck ends, and a practice tool that can't say what the right answer is can only show you a picture.
A phantom flips that. Each case is a dozen numbers: neck radius, sac radius, which slice the lowest renal comes off, where the sac peaks, where the bifurcation is, the two iliac radii. The image is drawn from those numbers and so is the reference, so they can't disagree. The page says plainly that these aren't patient images, because a practice tool that is vague about its own data teaches the wrong habit.
Nothing is stored. sliceHU(case, z) draws one 384 by 384 slice in Hounsfield units on demand: air, a body outline, a vertebra, kidneys that come and go with the slice, renal arteries running out sideways, and the aorta drawn last. Noise comes from a seeded generator, so slice 40 looks the same every time you come back to it. One slice is about 150,000 pixels, which is a few milliseconds, so there is no volume sitting in memory and nothing to download beyond the page.
That function is also the seam for real data. The viewer and the scoring only ever ask for a slice by index, so a loader that reads a stack of real images answers the same question without either of them changing.
export function sliceHU(c: EvarCase, z: number): Int16Array
The lumen in the sac is eccentric, pushed toward the front, with thrombus lining the back the way it usually does. On the angio window the bright contrast column is the eye-catching thing, and it is the wrong edge: EVAR diameters go outer wall to outer wall. The soft-tissue window is there so the wall is easy to find once you know to look for it.
Scoring needed definitions written down, because a tolerance on an undefined measurement isn't a tolerance. The neck ends at the first slice more than 10% wider than the neck. Diameters pass within 2 mm, roughly where experienced readers disagree with each other. Lengths pass within 5 mm, about two slices either way. Unmeasured tasks say so instead of failing, because skipping one isn't the same as getting it wrong.
A caliper is two clicks, which leaves out anyone who isn't using a pointer. The image takes focus, the arrow keys steer a crosshair (Shift moves five pixels), Enter drops each end, Escape clears, and Page Up and Page Down change slice. The measured length goes to a live region, so you hear the number as soon as the second point lands.
The buttons all say "Record caliper" on screen, with the task name in visually hidden text for screen readers. My first pass put the space inside the hidden span, and the test couldn't find the button. The text content read correctly, but the computed accessible name trims each child and the two halves ran together. A screen reader would have read it out as one word.
TestingLibraryElementError: Unable to find an accessible element with the role "button" and name `/record caliper as proximal neck diameter/i`
Update — October 22, 2026
One page with one standard is a test, not practice. I split it into three levels, and each one changes something real: which anatomy you get, whether you're told where to look, how close counts, and whether there's a clock.
Easy long neck hints ±3 mm / ±8 mm no clock Medium long + short neck none ±2 mm / ±5 mm no clock Hard short + hostile neck none ±2 mm / ±5 mm 5:00, hands in at 0:00
Hard needed a case worse than the short neck: 30 mm wide, about a centimetre long, with a right iliac wide enough to need the biggest limb. I first put the renal at slice 32 and the end of the straight neck at 36, which reads as 8 mm, and the reference came out at 14. The phantom flares the sac in on a smoothstep, and the scoring says the sac starts at the first slice more than 10% wider than the neck, not where the flare begins. The curve is so flat at the start that it takes three more slices to get there.
neckEndSlice 36, sacPeak 52, neck 15 mm, sac 35 mm z=37 t=0.063 r=15.22 (need > 16.5) z=38 t=0.125 r=15.86 z=39 t=0.188 r=16.85 <- sac starts here renal 34 -> neck length (39 - 34) x 2 mm = 10 mm
So the hostile case's renal sits at slice 34 and its flare begins at 36, and the test pins the neck length the scoring will actually use rather than the number I typed into the case.
Easy tells you which slices to look at: the lowest renal, where the aneurysm starts, the widest part of the sac, a stretch of iliac clear of the bifurcation. A range of plus or minus three slices would have handed over the answer as its midpoint, so each range sits a little off-centre, and a test checks the midpoint isn't the answer.
The countdown has role="timer", which isn't a live region by default, and that's right: a screen reader reading every second aloud would make the exercise impossible. Next to it, a polite live region stays empty until a minute is left, then thirty seconds, then time's up. At zero your answers are handed in as they stand, and the results line says how many landed and how long it took.
Handing in at zero happens inside the interval callback, not in an effect that watches the remaining time. The lint rules here don't allow setting state inside an effect body or reading the clock while rendering, and keeping the tick as the only thing that reads Date.now() is cleaner anyway. Start over resets the clock, which on a practice page is fine. It matters more once attempts are recorded, where the first try is the one that counts.
Update — October 22, 2026
The measurements only matter because of what they decide. So after measuring, you now pick the stent graft: which iliac the main body goes up, then an Endurant II/IIs main body, a contralateral limb, and anything extra on the main body's own leg, from the manufacturer's public sizing sheet.
A neck diameter maps to a main-body diameter, an iliac diameter maps to a limb diameter, and the catalogue says which combinations of diameter, leg and length exist. I transcribed it as data, rounded measurements to the whole millimetre the bands are written in, and treat anything off either end as "no standard device". I left out the one limb length the sheet marks as not available everywhere.
neck 19-20 21-22 23-25 26-28 29-32 body 23 25 28 32 36 iliac 8-9 10-11 12-14 15-18 19-22 23-25 limb 10 13 16 20 24 28
My first grading test picked a 13 mm limb for the long-neck case's 13 mm left iliac and expected a match. It failed, and the code was right: 13 falls in the 12 to 14 band, and that band gets a 16. A limb has to be oversized to seal, which is the whole point of the table, and I'd skipped straight past it. It also meant both of that case's iliacs land on 16, so it couldn't tell me whether a limb went to the right side. The side tests use the short-neck case instead, where the iliacs need 24 and 20.
AssertionError: expected [ 'match', 'mismatch', 'match' ] to deeply equal [ 'match', 'match', 'match' ]
Each pick is graded against what the table gives for the real anatomy. Next to it is what the table gives for your own measurements. When those two differ, the pick went wrong because a measurement did, and that's a different lesson from reading the table wrong. Only diameters are graded. Lengths come from a centerline, and an axial phantom doesn't have one, so lengths are listed for choosing but not scored.
The page says plainly that this is the public sheet, for practice, not affiliated with Medtronic and not for clinical use. A sizing table on a practice site that looks authoritative is a liability, and the instructions for use are the real source.
Update — October 22, 2026
The point of scoring people is to find out whether they get better. So signed-in users can now join a study: agree to a consent text, say where they are in training, and every attempt they check is saved to a record that can be compared over a career. Practice works exactly the same without joining, or without signing in at all.
A study needs ethics approval before its data can go in a paper, and this one doesn't have it yet. The consent version is 2026-10-draft, the form says so in its first line, and changing the text means changing the version, which re-stamps when each person agreed. Rows are keyed by a random participant id, and the export carries that id and nothing that names anyone.
The browser makes an id when an attempt starts and sends it with the answers. Checking twice, retrying after a timeout, or a request that landed but whose response didn't all send the same id, and the insert ignores the repeat. A duplicated attempt in a learning-curve study isn't noise, it's a fake extra practice session.
INSERT INTO evar_attempts (participant_id, client_attempt_id, ...) VALUES ($1, $2, ...) ON CONFLICT (client_attempt_id) DO NOTHING RETURNING *
The API validates every number, and my first bound was 300 mm on the grounds that no aorta is that wide. That's true, and beside the point: the study records what people actually measured, including the caliper someone drags corner to corner by mistake. With the 300 cap that whole attempt would have been rejected, and the most interesting wrong answers would never reach the data. The bound is now 1000 mm, which only stops garbage.
I considered a withdrawn flag and decided against it. If someone leaves a study, the honest version is that their data is gone, not filtered out of a query someone might forget to filter. Withdraw asks once, then deletes the participant, and the attempts go with it.
Update — October 22, 2026
The phantom computes every reference exactly, but exact only means exactly what I defined. If a vascular surgeon looks at a case and says the neck is 26, not 24, I want to change that number on a page, not in a geometry file. So there's now an admin page at /evar/admin that sets a case's five answers by hand.
Hints, the slice the sac starts on and the Hard-level clock all still come from the geometry. Only the scored values change, and if the API is unreachable the page quietly scores against the phantom, because practice shouldn't break when an admin feature does.
const row = overrides.find((o) => o.caseId === c.id);
if (!row) return phantom;
return { ...phantom, neckDiameter: row.neckDiameter, neckLength: row.neckLength,
maxSac: row.maxSac, rightCia: row.rightCia, leftCia: row.leftCia };A correction changes scores for everyone from the next load. For practice that's the point. For the study it would be a quiet disaster if old attempts were re-scored against the new key, but each recorded score already carries the reference it was judged against, so an analysis can see exactly which key was live.
scores: [{ id: "neckDiameter", yours: 24.2, reference: 26, verdict: "outside" }, ...]My first idea for Reset to phantom was to key each case's form on when it was last saved, so a reset would remount it with the phantom's numbers. It would have, and it would also have remounted after every save, wiping the confirmation the moment the refetch landed. Reset now puts the phantom values back itself, and the form stays mounted.
Update — October 22, 2026
The API has served the study export to admins since the research tracking landed, but only as JSON from a curl. The admin page now has a study data card that says how much has been recorded and downloads it as a CSV or as the raw JSON.
Participants and attempts come back separately, so a training level isn't repeated on every attempt. Anyone opening this in a spreadsheet or R wants the opposite: one row per attempt with the profile next to it, and every measurement and device grade as its own column. So the CSV joins them, and an attempt whose participant isn't in the export keeps an empty profile rather than disappearing.
participant_id,training_level,training_year,specialty,consent_version,attempt_id,case_id,level, app_version,started_at,submitted_at,duration_ms,time_limit_ms,timed_out, neckDiameter_yours,neckDiameter_reference,neckDiameter_verdict, ... leftCia_verdict, ipsilateral_side,mainBody_code,mainBody_picked,mainBody_expected,mainBody_verdict, ... ipsilateral_verdict
Specialty is free text, so it needs quoting for commas, quotes and line breaks. I had that half written before I found the shared CSV helper, which also defuses a cell starting with =, so a participant can't type a formula that runs when I open the file. Mine didn't do that.
specialty: =HYPERLINK(1) -> '=HYPERLINK(1)
A measurement nobody made, or a limb nobody picked, is an empty cell, so a spreadsheet treats it as missing rather than averaging in a zero. The JSON download is there for anything the flattening loses.
Update — October 23, 2026
The practice worked, but it read like a form. The scan was a 576px square in a page of stacked sections, and finishing a case dropped a table under the buttons. So I gave the scan the screen and made finishing a case feel like finishing something.
The page is now a dark stage the height of the screen, dark in either site theme the way a reading room is. A top bar holds the level, case, clock and best. The measurements and the device picker sit either side of a viewer sized to whatever height is left, and the window, slice and caliper controls live in a dock that stays on screen while scrolling. The dark comes from nesting the theme rather than hard-coding colours, so every token underneath still works:
<div data-theme="dark" className="bg-background text-foreground"> ... <SliceViewer className="max-w-[min(100%,calc(100dvh_-_17rem))]" />
A pass is worth 50 just for landing inside tolerance, and up to 100 for landing on the answer, so a measurement right on the edge still beats one just outside it. Device sizes that match the table add 50 each, Hard adds a bonus for time left, and the level scales the lot. Stars ignore all of that and count measurements within tolerance, because measuring is the skill this exists to practise. A perfect device pick on wrong numbers shouldn't look like a good run.
measurement 50 + 50 × (1 − |off by| / tolerance), 0 outside device 50 per size that matches the table time bonus Hard only, 100 × time left / 5:00 level ×1 Easy, ×1.5 Medium, ×2 Hard stars 5 within → 3, 4 → 2, 3 → 1
Bests live in localStorage per level and case, because practice is anonymous and there's no account to hang them on. The catch is that the best gets written the moment a case finishes, so by the time the popup asks whether this run beat it, the stored best already is this run. The popup compares against the best from when the attempt started instead, read once on Try again, Next case or a level change.
const [bestAtStart, setBestAtStart] = useState(() => bestFor(medium, 0));
// ...
useEffect(() => {
if (total !== null) recordBest(level.id, evarCase.id, total);
}, [total, level.id, evarCase.id]);The study records an attempt once however many times its answers are checked, and a test pressed Check answers twice to prove it. With the results in a modal, the stage behind it is hidden from assistive tech and Check answers becomes Show results once a case is done, so the second press had nothing to find:
TestingLibraryElementError: Unable to find an accessible element with the role "button" and name `/check answers/i`
The guarantee still mattered, just through a different door. The test now closes the popup to review the scan and opens it again, and still expects exactly one recorded attempt.
Update — October 23, 2026
A few hours after the stage shipped, I looked at it in light mode. The header was light, and everything under it was near-black.
The stage set its own theme on a wrapper, on the reasoning that CT is read in a dark room. It worked exactly as written, which is why nothing caught it: every token resolved, contrast held, the tests passed. But someone who picked light mode had picked light mode, and a dark slab under a light header reads as broken, not as a reading room. Only the scan needs to be black, and the canvas already is.
- <div data-theme="dark" className="bg-background text-foreground"> + <div className="text-foreground">
The same screenshot showed the dock letting the task rows read through the slider while scrolling. The panels are glass because there's only the background behind them. The dock moves over text, so it gets a near-opaque surface instead.
const dock = "rounded-2xl border border-border bg-surface/95 p-4 shadow-lg backdrop-blur";
Update — October 23, 2026
Easy had one case, so once you'd done it there was nothing left to practise on. And the slices looked like a diagram: a bright circle on a grey oval, with a round bone underneath.
I couldn't pull an open aortic CTA set down from where I was working, and the sets I know of are mostly normal aortas anyway. Each case would also need its five answers measured by hand before it could be scored. So the phantom got more convincing instead, and real cases stay on the list below.
Each case is still just a dozen numbers, so adding six was cheap. The new ones are picked so each level teaches its own thing: Easy gets anatomy any standard device fits, Medium gets narrow iliacs and the wide iliac on the other side, and Hard gets a neck a millimetre under the usual landing length and an 8 cm sac with both iliacs on the widest limb.
easy: ["long-neck", "small-sac", "wide-sac"] medium: ["long-neck", "short-neck", "narrow-iliacs", "ectatic-left"] hard: ["short-neck", "hostile-neck", "short-wide", "giant-sac"]
The titles lost their numbers on the way. Easy would otherwise have read Case 1, Case 4, Case 5.
Everything around it is now drawn too: the IVC on the patient's right, pushed further over by a big sac; the liver and spleen at the top of the stack; kidneys in the arterial phase, with a bright cortex, a darker medulla and fat in the sinus; psoas thickening toward the pelvis; a vertebra with laminae and a spinous process; bowel loops with gas floating above a fluid level; and the scanner table under the patient. None of it moves the aorta or the iliacs, so every reference answer is exactly what it was.
The old noise was independent at every pixel. Real CT noise is grainy, because neighbouring pixels share their reconstruction, and edges are slightly soft from partial volume. Now the tissue gets a small blur, then noise built on a coarse grid and interpolated, with a little fine speckle on top. A test checks neighbouring pixels in the lumen actually move together.
const coarse = Float32Array.from({ length: cells * cells }, () => (random() + random() + random() - 1.5) * 36);
...
out[y * SIZE + x] = top * (1 - fy) + bottom * fy + (random() - 0.5) * 16;It counted air inside a box in the middle of the slice, and the box reached past the edge of the old body outline, so it was counting the room. I only noticed because a red test came up green. The box is tighter now, and it failed first, the way it should have.
I set a budget of twice the old cost per slice. The first version was over it. Building ellipses inside the pixel loop was some of it, but most of the remainder was Math.hypot in the bowel and canal checks, called on every pixel in the abdomen. Squared distances do the same job.
before 11.5 ms per slice first pass 26.7 ms ellipses hoisted 23.7 ms no Math.hypot 20.7 ms (1.8x, inside budget)
Update — October 23, 2026
A personal best tells you that you got better once. It doesn't tell you whether you're getting better, which is the whole point of practising.
/evar/results shows a card per level with attempts, the average number of measurements within tolerance and the best points, a line of measurements within tolerance attempt by attempt, and a table of every attempt, newest first. The table is the text version of the chart, so the chart itself is hidden from screen readers rather than described twice.
{ id, levelId, caseId, finishedAt, within, stars, total, timedOut,
deltas: { neckDiameter: 0.4, maxSac: -1.2 } }Practice is anonymous for anyone outside the study, and the study already keeps its own record for people who consented. Putting everyone's practice on the API would mean an account or a tracking id for people who only came to measure a neck. So the history sits in localStorage next to the personal bests, capped at 500 attempts and checked against a schema on the way in, so garbage reads as an empty history rather than a crash.
I built the entry in render and recorded it in an effect that depended on it. The entry was a new object every render, so the effect ran every render too, and only the id-based de-duplication stopped the history filling up. The lint caught it before a test did:
The 'historyEntry' conditional could make the dependencies of useEffect Hook change on every render.
It now works the way the study panel already did: a set of attempt ids already kept, checked inside the effect, so each attempt is written once with the result it finished with.
Update — October 23, 2026
The study download was the right shape for analysis and the wrong shape for a quick look. To answer "are the students timing out on Hard?" I had to download a CSV, open it and build a filter by hand, every time.
/evar/admin/results reads the same export the download card uses, through one shared query, and narrows it in the browser by level, case, training level, timed out and a date range. There is no new endpoint and no query language on the API. The study is a few hundred attempts at most, so filtering them in memory is cheaper than another round trip, and the rows the page shows are exactly the rows the CSV would have.
filterStudyRows(rows, { level: "hard", caseId: null,
trainingLevel: "medical-student", timedOut: true,
from: "2026-10-01", to: null })The summary table gives, for each of the five measurements, how often it landed within tolerance out of how often it was taken. A timed-out attempt that never got to the iliacs counts as not measured rather than missed, so the share answers "when people measure this, do they get it right" instead of blending that with "did they run out of time". The timed-out filter is there for the second question.
"Download these as CSV" writes the filtered rows with the same columns as the full export, so a cut I find on the page goes straight into R without redoing it. The filters live in the page, not the URL, which keeps it simple and means a filtered view can't be shared as a link yet.
Update — October 23, 2026
A slice is 384 pixels across at 0.85 mm a pixel, so the 2 mm diameter tolerance is a little over two pixels. On a laptop that's tight. On a phone, where the whole slice is narrower than a thumb is long, it was mostly luck. The viewer zooms now, from 1× to 8×, and pans.
Caliper points were already stored in image pixels, and that's what made this small. Zoom is a scale plus the image point sitting in the middle of the viewport. Drawing goes through it, and so does turning a click back into an image point, but the points themselves don't change. distanceMm, the scoring and the live readout are untouched, and the test I cared most about says ten pixels is the same number of millimetres at 4× as at 1×.
// zooming keeps the anchor under the pointer const ratio = view.scale / scale; x: anchor.x - (anchor.x - view.x) * ratio, y: anchor.y - (anchor.y - view.y) * ratio,
Before, a point went down the instant the mouse did. With panning, the same press might be the start of a drag, and there's no way to tell until it moves. So a point is placed when the press ends, and only if it wandered less than 4 screen pixels. Anything further is a pan. Two fingers make a pinch, which never places anything, even when one of them lifts first.
+ and − zoom around the crosshair, 0 resets, and the arrows pan the view along when the crosshair walks off the edge, so a keyboard user never steers a cursor they can't see. The zoom level sits in a live region beside the buttons. The scroll wheel needed a listener attached by hand, because React adds wheel listeners as passive, and a passive listener can't stop the page scrolling underneath the image.
Zoom carries across slices, because scrolling down a neck at 4× is the point, and resets when the case changes. The canvas is drawn at twice the slice's size so the caliper lines stay sharp when the anatomy under them is enlarged eight times.
Update — October 23, 2026
The organs around the aorta made the slices look right, but the neck, the part that decides the device, was still a parallel round tube with nothing in its wall. Every case now has at least one thing a real neck has: a taper or a flare, a lean that makes it oval on an axial slice, a crescent of thrombus, or calcified plaque.
Cut a tube that leans at θ with a horizontal plane and you get an ellipse whose short axis is the real diameter and whose long axis is that divided by cos θ. So the phantom draws each vessel in its own frame: squash the long direction back by the stretch, then decide wall, thrombus, lumen or plaque as if it were round. At 50° the hostile neck's 30 mm reads nearly 47 along its long axis. On three of the cases, measuring the long axis moves you up a main body size, and on the hostile neck and the giant sac it takes you off the sheet. The measuring note now says to take the short axis.
const along = (dx * toward.x + dy * toward.y) / stretch; const across = -dx * toward.y + dy * toward.x; // ...then everything is decided on a round section
The neck runs to where the aorta first passes 110% of its diameter at the renals. On a neck that widens on the way down, that happens before the sac visibly starts. The wide left iliac case now flares from 24 mm, and its neck length dropped from 22 mm to 8 without the sac moving at all. That's the lesson, so the debrief says it.
I'd first put the flare on the wide sac case, which is on Easy. It made that neck 10 mm long, under every device's minimum, and a case that hostile doesn't belong on the level that promises straightforward anatomy. The flare moved to a Medium case, and the wide sac got a calcified arc instead.
The test walks round the wall a degree at a time and counts how much of the plaque arc is bright. On the hostile neck it found half of what it expected:
AssertionError: expected 30 to be greater than 36
The drawing was right. The arc is defined in the vessel's own frame, and on an oval that squashes it into fewer degrees on the image, so a 60° arc covers about 42° of screen. The test now checks plaque on a round neck, where the two frames agree, and the oval is covered by its own test.
A crescent of thrombus shrinks the lumen and pushes it away from that side, and the outer wall stays exactly where the reference says it is. The contrast edge is the easy edge to measure to and the wrong one, and now three necks punish it. Calcified plaque does the same thing from the other direction: it's the brightest thing on the angio window, it sits in the wall, and the outer edge is past it.
Only one reference moved, but every image did. A best set on a round neck isn't one to beat on an oval one, so device history and personal bests moved to new storage keys and the old ones are deleted.
Update — October 23, 2026
Device lengths were listed but never graded, because a length is measured along the vessel and an axial stack only knows how far apart two slices are. Once the necks could lean, that gap stopped being a footnote: the hostile neck is five slices long, 10 mm on the scanner's z axis, and 16 mm along the aorta.
centreAt and iliacCentresAt already say where the vessel is on every slice. The centerline is those points joined in 3D: each step is the slice spacing, plus however far the centre moved sideways. Down a straight neck that's 2 mm a slice. Through a neck leaning 50° it's about 3, and down an iliac heading out toward the hip it's a little over 2.
total += Math.hypot((q.x - p.x) * c.pixelMm, (q.y - p.y) * c.pixelMm, c.sliceMm);
Neck length now runs along it, for the answer and for your marks alike: you still pick the renal and the sac start on the slices, and the distance between them is measured down the vessel. Two debriefs changed because of it. The short, wide neck is 14 mm on the slices and 15.5 along the vessel, which moves it from just under the usual minimum to just over.
The IFU's rule for overall length is lowest renal to just above the internal iliac. The phantom's common iliacs ran off the bottom of the stack without branching, so each one now gives off an internal iliac, back and out toward the pelvis. My first version sent it straight back, and the test that probes for contrast behind the common iliac found bone instead: the iliacs run over the vertebral body, so straight back is into it.
AssertionError: right: expected 612 to be less than 150
Three new slices to mark sit under the neck: the aortic bifurcation and each internal iliac origin. They aren't scored tasks, which would have meant new API columns. They give your own lengths, and those feed the device grading.
Endurant's sheet gives each limb's total contralateral covered length with a bifurcated body: the limb plus 50 mm, assuming the minimum 30 mm of overlap, and 10 mm less on the 124 mm body. More overlap is allowed, up to five stents, so a limb really reaches a range, not a number. The same footnote puts the end of the contralateral gate 80 mm down, and the IFU wants that above the bifurcation.
gate ends 80 mm down (70 on the 124 mm body), above the bifurcation contralateral limb + 30 to 50 mm ipsilateral body, or body + extension - 30 to 50 mm overlap Endurant IIs ipsi limb + 50 to 70 mm a side lands 15 mm into its common iliac .. the internal iliac origin
On the hostile case the slices put the bifurcation 76 mm below the renal, and I wrote that only the 124 mm body's gate would clear it. Then I printed the centerline: 101 mm. The sac pushes the vessel forward off the spine and back again, and the centerline bows with it, so every case has 100 to 118 mm from renal to bifurcation and every gate fits. That's the same lesson as the neck, from the other end: the axial distance is the one that's easy to read and the one that's wrong.
The results get a Lengths table under Devices, with where each side has to end for the real anatomy and where your marks say it does. The study payload still records the three diameter grades, because the API caps that list at five and length verdicts can be worked out again from the device codes it already stores.
Update — October 23, 2026
With only Endurant on the page, "which limb does this iliac take?" had one answer, and that made the table look like anatomy. It isn't. Each manufacturer oversizes differently, so you can now pick Gore Excluder Conformable or Cook Zenith Alpha instead, and the same measurements get graded against that device's own table.
22 mm common iliac Endurant II/IIs 24 mm limb Excluder Conformable 27 mm leg Zenith Alpha no standard leg (the table stops at 20)
What goes on the neck, what goes in an iliac, what's in the catalogue, how far each side reaches, and how much seal it needs. That became a Sheet type, and the grading from the last two updates moved out of the Endurant file to read whichever sheet a pick came from. Gore's comes from the IFU the FDA hosts for the Conformable, and Cook's from its own Zenith Alpha IFU.
Endurant and Cook write their bands in whole millimetres with no overlap. Gore writes the iliac bands to the half millimetre, and 12 to 13.5 is followed by 13.5 to 14.5, so a 13.5 mm iliac is allowed a 14.5 or a 16. The grading had assumed one right answer per row, so the expected size became a list, and the results read "14.5 or 16 mm". The study API stores one number there, so it gets the first, next to a verdict that already says whether the pick was one of them.
I wrote a test that every case has some stack that lands on both sides with every sheet. Endurant and Cook passed. Gore failed on the first case it tried:
AssertionError: excluder long-neck left: expected false to be true
Gore counts 5.5 cm of trunk plus the leg's label, and its shortest leg is 9.5 cm, so its contralateral side always reaches at least 150 mm. The phantom's internal iliacs came off 140 to 153 mm from the renals, because a 100-slice stack left room for only about 40 mm of common iliac. Real ones run nearer 50 to 60. So the stack grew to 120 slices and the internal iliacs moved down to about 60 mm along each iliac. The device was fine. The phantom had been built short to fit the scroll bar.
Endurant's codes are Medtronic's, and the Excluder trunk codes are in the FDA summary. Neither document lists Gore's leg numbers or Cook's part numbers, so those are built from the table's sizes, and the picker says which is which. A practice tool that invents official-looking part numbers is teaching something false.
Update — October 23, 2026
The first section of this page says I wanted real scans and shipped a phantom because a segmentation doesn't come with an answer key. That's still true, but the admin page fixed the answer key: a case can have its five answers set by hand. So Medium now ends with a real, deidentified CTA of an infrarenal aneurysm.
I measured every segmentation in the AVT collection rather than trust the description. Fifty-six scans, and the infrarenal aorta is 16 to 26 mm wide in all but one. The two openly licensed 4D-CTA aneurysm sets on Zenodo are real aneurysms, but cropped to about 70 mm round the sac, with no renals and no iliacs, which is everything a sizing exercise needs. The one AVT case that is an aneurysm turned out to live in a folder that said so all along.
'Rider/R6 (AAA)/R6.nrrd' 296.2 MB 'Rider/R6 (AAA)/R6.seg.nrrd' 0.4 MB
A script crops it to 256 pixels square round the aorta and iliacs at its own 0.72 mm spacing, averages it into 2 mm slices, and keeps from about 4 cm above the renals to the internal iliacs. The first try gzipped to 9 MB and barely shrank, because CT noise doesn't compress. What did work was noticing that the two windows only ever show −160 to 450 HU, each spread over 256 greys, so one byte a voxel at 2.4 HU a step loses nothing anyone can see.
{ "size": 256, "slices": 127, "pixelMm": 0.7246, "sliceMm": 2,
"huMin": -160, "huStep": 2.4, "bytes": 7051231 }The values in this file are stored with a +1024 offset, so my first picture of it was solid white until I subtracted it. It's fetched when the case is opened, never with the page, and gunzipped in the browser.
There's no geometry behind a real scan, so the honest default is no answer. Until its five numbers are saved on the admin page, the case says it isn't scored, the end shows your measurements without a verdict, and nothing goes to the study, the results page or a personal best. Once they're saved it scores like any other case. Lengths on it run straight down the slices, because it has no centerline yet, and the page says that too.
The scan is CC BY 4.0, from AVT on figshare, which builds on TCIA's RIDER collection. The attribution sits under the case whenever it's open, and the folder it's served from has a note of what I changed.
Update — October 23, 2026
Three levels, ten cases, five measurements, five slices to mark, three manufacturers, zoom, and a dock of controls. Someone landing on it for the first time had no way in except to start clicking. It now has the guided tour ZeroProof got first.
The engine is shared: FeatureTour renders the button and the overlay, and its hook remembers per page whether you've seen it. All this page adds is eight steps and an id on each part they describe. The first step asks before anything gets spotlighted, and it opens by itself only once.
evar-intro evar-levels evar-cases evar-scan evar-measurements evar-devices evar-dock
Every page test starts with empty storage, which to the tour looks like a first visit, so each one would have run under an overlay. The shared render helper marks the tour seen, and the tour has its own four tests, the same ones ZeroProof's has: it asks on a first visit, stays shut once seen, reopens from the button, and walks to the end.
Update — October 23, 2026
Every update above added something worth having, and every one of them added it to the screen. By the end, the left panel had thirteen rows, the right had a full device picker and a five-line disclaimer, and the scan had a paragraph of controls under it, all visible from the first second. Meanwhile the one thing that should come first, whether you want to be in the study, was at the very bottom of the page.
A first-time visitor who hasn't joined gets a dialog about the study before the tour or the scan. Signed in, it's the consent form itself. Signed out, it's sign in or practise without joining. The answer is remembered, and the tour waits for it: the shared tour hook grew an autoOpen flag so a page can hold its first-visit open back until something else is done. The panel at the bottom stays, for your record and the way to withdraw.
Putting the consent form in a dialog put it on the page twice, and the test for consenting in the dialog couldn't find the training level:
TestingLibraryElementError: Unable to find an accessible element with the role "combobox" and name `/training level/i`
Both copies used the same hard-coded ids, so the dialog's label pointed at the panel's select. The form takes generated ids now.
The left panel is Measure and Size the graft, with Measure counting how many of the five you've recorded. The device column went with it, so the scan has the width it was sharing. The tour opens each tab as it reaches it, the way ZeroProof's switches tabs.
Diameters and the neck length stay open, because they're the task. The landmarks only graft lengths need, the measuring rules, the viewer controls, the sizing tables' source and the real scan's full citation each fold behind a labelled disclosure. On the real scan, the one-line credit and its licence stay visible. Nothing was removed, and the viewer's controls are still its description for screen readers while they're folded.
Update — October 23, 2026
After eight updates in a day I went through the whole feature as if someone else had written it: correctness, speed, accessibility, consistency, and whether it would survive the next step, which is hundreds of real scans from an actual source instead of one. Twelve things came out of it, plus three asks along the way. The ones worth writing down are below.
A phantom slice took 40.8 ms. Most of that was the renal arteries: to decide whether a pixel sat on one, they worked out where the aorta's centre was, and that walks the neck slice by slice. Once per pixel. A test that counts the calls said exactly how bad:
AssertionError: expected 145933 to be less than 10
Working the renal and iliac geometry out once per slice took it to 20.7 ms. The worse half was that a slice was being drawn on every re-render of the page: every caliper click, every mark, four times a second on Hard. I'd written a comment saying the React Compiler kept the slice function stable. The compiler isn't switched on in this app, so the comment described something that never happened. Slices are cached where they're made now, so it doesn't matter who asks or how often. Hard's clock moved into its own component, so the page stopped re-rendering with it.
R6 is 7 MB, written into the code and committed. At a few hundred scans that's gigabytes of repository and a code change for every case. Now there's a manifest beside the files, checked against a schema, with each dataset's citation and licence written once and attached to every scan from it. Point NEXT_PUBLIC_EVAR_SCANS_URL at object storage and the files and the list move together; the CSP picks up the origin. The prep script now adds its own manifest entry, so a new scan is one command and two uploads. Re-running it on R6 rebuilt the committed file byte for byte.
node scripts/prepare-evar-scan.mjs R7.nrrd avt-r7.u8.gz --offset 1024 \ --top 300 --bottom 550 --cx 290 --cy 250 \ --id avt-r7 --dataset avt --case R7 --title "AVT R7"
The pages had to hold that many, too. Real scans pick from a select next to the phantom pills, and the admin page lists every case as a row that only builds its form when opened, with a search and a filter for scans still waiting on answers. Before, a real scan showed up as avt-r6 in your results and the study panel, because each page looked titles up in its own list of phantoms; there's one lookup now.
The previous update's checks failed on two tests that waited for the scan to finish loading. Decoding 8.3 million voxels with a callback and a rounding per voxel took 383 ms here and over a second on CI, and blocked the browser the same way. A byte only has 256 values, so a lookup table took it to 39 ms. Here the volume stays one byte a voxel and decodes a slice at a time, the download is cancelled if you move on, it's released half a minute after you leave it, and a scan that won't load says so with a Try again instead of loading forever.
Scrolling over the scan zoomed it, which no radiology viewer does and which trapped the page whenever the pointer crossed the image. The wheel steps through slices now, adding up small trackpad scrolls, and Ctrl or Command with it zooms, which is also what a pinch sends. The zoom readout had been a live region, so a wheel zoom read out every step to a screen reader; now only the button and keyboard steps are announced.
The measurement panel made the page taller than the window, and the scan's size was a guess at the header and dock heights that left its bottom behind the dock once the header wrapped. On desktop the stage is exactly one screen now: the panel scrolls with its tabs pinned, and the scan sizes to the height it actually has through a container query. The page also opens on Medium's real CT, read on the server so it doesn't swap in after load, and anyone on the admin allowlist gets an Admin link instead of having to know the URL.
The stores were tidying away old keys on every read, so I added a flag to do it once, and called it retired, in a function that already had a local called retired. The assignment threw inside a try, the error was swallowed, and every best read back as nothing:
AssertionError: expected null to be 400 // Object.is equality
The existing tests caught it before it went anywhere. Typecheck would have flagged it as well; I just ran the tests first.
Update — October 24, 2026
Before moving this to its own domain I wanted to know what it would cost to run, so /evar/plan now says what the practice is for and then prices it: storage, servers, a resident's time, the domain and everything else, in Canadian dollars, with sliders for the library, the traffic and how long it runs.
Running the site is Railway's US$5 minimum, a domain, and storage counted in cents: about $99 a year at its quietest and $353 at its busiest. What costs money is a resident setting each scan's five answers. Fifteen minutes at $50 an hour is $12.50 a scan, so a thousand scans is $12,500 and 250 hours of someone's evenings. The range across everything I asked about:
How long Smallest Middle Biggest 3 months $160.65 $1,285.71 $12,599.35 1 year $223.67 $1,348.94 $12,853.48 2 years $322.34 $1,447.87 $13,210.52
My first pass at the model converted each line to Canadian dollars once, over the whole period. A year of Railway came to $83.96 while the same page said $7.00 a month, and anyone multiplying that out would find four cents missing and stop trusting the rest. Each bill is converted on its own now, a month of Railway or a year of the domain, so twelve months at $7.00 are exactly $84.00. Storage is the one exception: a month of a hundred scans is about two cents, and rounding it monthly would have understated the year by a fifth.
CloudFront's first terabyte a month is free, which is about 141,800 scan opens, and only the busiest corners of the usage grid go past it. At the very top, 100 people a day doing 100 scans each, paying by the gigabyte would cost more than six times the flat-rate plan, so the model takes whichever is cheaper for the month:
2,115 GB a month, 1,115 GB past the free terabyte by the GB: 1,115 x US$0.085 = US$94.78 flat-rate Pro: US$15.00 for up to 50 TB
Stryker left eight mutants alive on the first run, a 95% score. The names of the delivery plans could be blanked, and three usage figures could divide instead of multiply, because the tests checked them against a ceiling, or over one month, where multiplying by the months and dividing by them are the same thing:
[Survived] ArithmeticOperator src/lib/evar/costs.ts:192:16 - recordsGb: recordsGbPerMonth * months, + recordsGb: recordsGbPerMonth / months,
Pinning the plan for each case and the exact page data, CPU and records over two years killed all of them. The one left is the boundary where both plans cost exactly US$15, which can't change a number, so it's marked as equivalent rather than tested.
Update — October 24, 2026
When this moves to its own domain it needs a front door, so /evar/welcome says what it is, asks the study question on the page instead of in a dialog, and has a 47-second video of a case. I didn't want stock footage or a presenter reading a script, so the video is the practice recording itself: a script drives the real page, takes a screenshot after every step, and the captions come from the same list the page writes out as the transcript.
Playwright can record a session, but only as WebM, and an iPhone won't reliably play that. The usual fix is ffmpeg, which isn't on this machine, and I didn't want a binary dependency for one video. macOS already has an H.264 encoder, so a short Swift script hands the screenshots to AVFoundation, holding a still frame for as long as its scene needs, which costs almost nothing once encoded. What came out, read back by AVFoundation:
duration 47.00 s, 1280x720, 30.0 fps, 651 kbps, codec ["avc1"], audio tracks 0
A demo that measures badly is worse than none, so the recorder imports the phantom and asks it where the aorta's outer wall is on each slice, then clicks there through the same zoom maths the viewer uses. Node can run the TypeScript directly now, until the sizing sheets import each other the way the bundler likes, without extensions:
ERR Cannot find module '.../src/lib/evar/devices' imported from .../src/lib/evar/sheets.ts
Ten lines of resolve hook add the .ts, and every measurement in the video scores within tolerance.
For the graft I took the first main body and limb whose diameters matched the table. Diameters were right; the catalogue lists the shortest of each first, though, and the results said so:
Contralateral reach 102-122 mm 126-178 mm ✗ Misses Ipsilateral reach 124 mm 126-173 mm ✗ Misses
The recorder now searches every main body, limb and extension for a pick where the diameters match and gradeLengths says every length lands, which the case has.
Laid over the page, a caption sat on top of Check answers just as the video clicked it. Moved to a band under the page, it was hidden by the player's own controls on the poster, since those sit at the bottom of every video. The page now renders at 1280 by 640 with an 80 px band above it, which nothing covers.
Update — October 24, 2026
The plan priced a resident's time to set each scan's answers into every total, and it swamped everything else. A resident on the study may well set them for nothing, so it's a switch now, off until someone turns it on, and the page also says what I charge for looking after it and who owns what.
At $50 an hour and 15 minutes a scan, the resident was $1,250 of the middle case's $1,348.94 for a year, 93% of it, so the page was mostly a price for someone's evenings. With the switch off, the calculator drops the rate and minutes sliders and the resident's line, and the range and library tables follow it, because one provider around the cost sections holds the answer for all of them.
Two fees of mine joined the totals: a $500 base fee, once, and a 10% upkeep fee for looking after the site. The first version of the upkeep fee was 10% of the whole total, resident included, which isn't what it's for:
first pass My fee (10%) $134.89 10% of $1,348.94 now My upkeep fee (10%) $9.89 10% of $98.94, running the site only
The upkeep fee is a tenth of servers, delivery, storage, the domain, the website and sign-in, and never of the resident's time or the base fee. The middle case for a year is $608.83 with the switch off and $1,858.83 with it on.
The totals use a regular .com at Cloudflare's at-cost price, and the page now says so where the domain is priced and on its line in the breakdown: another ending costs more or less, a premium or already-owned name can cost hundreds or thousands, and registries can raise renewals.
Update — October 24, 2026
The practice showed where to click but never said how to measure, and a first visit opened on a popup about the study. A first visit now lands on /evar/welcome, which has a second video on what to look for and where the calipers go, and /evar/guide goes through every measurement with a picture of it.
Redirecting on the server means knowing someone has been before, which means a cookie, and this site only sets the ones it doesn't strictly need after consent. So it's localStorage, read by a script that runs before the page paints, the same trick the theme uses to avoid a flash. If storage can't be read it does nothing, so a locked-down browser gets the practice rather than a loop. This is all of it:
(function(){try{var s=window.localStorage;if(s.getItem("evar-welcomed")!=='true'&&s.getItem("evar-study-asked")!=='true'){window.location.replace("/evar/welcome");}}catch(e){}})();That covers a full page load. A click from elsewhere on the site swaps the page in without loading it, so the script never runs, and a small client component makes the same check instead. Anyone who answered the old popup counts as welcomed already.
I wanted the guide to match how it's done in a hospital, not just how my practice grades it, so I read it against the 2024 ESVS guidelines and the Endurant instructions for use. The five measurements hold up: outer wall to outer wall, across the short axis, from the lowest renal to where the aorta first widens by more than 10%. What real planning adds is a centreline through a 3D rebuild of the CT, and a set of limits every case has to fit inside:
ESVS 2024, Table 13: the range across current devices neck diameter min 16-19 mm, max 28-32 mm neck length min 10-15 mm neck angle above the renals 45-60°, below 45-90° calcium, thrombus at most 50% of the neck's circumference aortic bifurcation min 12-21 mm access arteries min 5-8.5 mm on the main body's side, 3.5-7 mm on the other
The guide covers all of it in a section on what real planning adds. The practice doesn't ask for any of it yet. The neck's shape, how much of it is lined, the bifurcation and the access arteries, and a last check that the case fits the device's instructions for use are next. Neck angles stay in the guide for now.
The neck is measured just below the lowest renal, and the intro had always done that one slice down. Recording the how-to with labels on, the left caliper landed where the renal artery met the wall, because a 3 mm artery on 2 mm slices still shows on the next one:
const dz = Math.abs(z - renal.slice) * SLICE_MM;
return dz > RENAL_RADIUS_MM ? [] : [{ side: renal.side, halfPx: Math.sqrt(RENAL_RADIUS_MM ** 2 - dz ** 2) / PIXEL_MM }];
one slice down dz 2 mm, the artery still 2.6 px either side of its line
two slices down dz 4 mm, goneThat's partial volume, and a patient's CT does it too. Both videos measure two slices down now, where the outer wall is a clean edge, and so does the guide's picture.
The command palette's floating pill sits in the bottom right of every page, and on the practice that corner is the end of the dock, so it sat on top of Start over in every frame. It's hidden on the practice now, the way it already was on the landing page, and ⌘K still opens the palette. The other was in the results:
Proximal neck diameter 23.0 mm 23.0 mm -0.0 ✓ Within tolerance
A caliper a few hundredths of a millimetre short rounds to the answer and kept its minus sign. Anything that rounds to nothing reads 0.0 now, with no sign either way.
Its recorder opened the practice and waited for the study dialog before doing anything else:
const studyDialog = page.getByRole("dialog", { name: /research study/i });
await studyDialog.waitFor();With the popup gone that never resolves, and a fresh browser is sent to the welcome page first anyway. It starts on the welcome page now, shows the question there, and follows Practise without joining into the practice. Both recorders share one module for the browser, the captions, the cursor and the calipers, and the how-to saves the guide's seven pictures in the same run as its video, so the two can't disagree.
Update — October 25, 2026
The last thing on the upcoming list was a domain of its own, and it has one: the practice is its own project now, deployed at medical.paulsumido.com. Everything EVAR is gone from this site except this write-up and the history in the changelog, and every old link lands on the same page over there.
On a site that's only EVAR, /evar is noise. The welcome page is the homepage, which is what the upcoming list asked for, and the practice is /practice. So two pages change name and the rest keep theirs, and the order matters because the first match wins:
{ source: "/evar", destination: `${MEDICAL}/practice`, permanent: true },
{ source: "/evar/welcome", destination: `${MEDICAL}/`, permanent: true },
{ source: "/evar/:path*", destination: `${MEDICAL}/:path*`, permanent: true },They sit in next.config.ts, which Next checks before the proxy runs, so an old link costs one 308 and never renders anything here. The hub card links out the way Ketsup's does, and this page stays where it is.
Personal bests, the results page and whether you'd seen the welcome page all live in localStorage, and localStorage belongs to an origin. paulsumido.com and medical.paulsumido.com are two, so anyone who practised here starts the new site with an empty history and gets the welcome page again. Study attempts are different: they're on the API, which the new site calls the same way, so a participant is still a participant there. Losing the history is the reason this went out as 9.0.0 rather than a minor bump.
The pages, the API proxy, the lib and the scripts were their own folders and went in one go, along with 16 MB of videos, pictures and the real scan. The work was everywhere else the practice had reached into: the public routes, the admin gate, the query keys, the command palette hiding its pill over the dock, the CSP origin for scans in object storage, a colour token in both themes, the test server's mock handlers and the accessibility scan's route list.
.env.example | 7 - e2e/public/a11y-routes.spec.ts | 6 - src/components/CommandPalette/CommandPaletteRoot.tsx | 10 +- src/lib/csp.ts | 11 +- src/lib/protectedPaths.ts | 3 - src/lib/publicRoutes.ts | 5 - src/lib/queryKeys.ts | 10 -- src/proxy.ts | 1 - src/styles/tokens.css | 2 - src/test/server.ts | 3 +- 153 files changed, 7 insertions(+), 14004 deletions(-)